Hitachi GR2000 Series Bedienungsanleitung Seite 217

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 500
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 216
Filtering/QoS Information
GR2K-GA-0014 1-175
Ver. 07-02
Description: This parameter specifies an EXP field value. The number of
packetsthatcoincidewiththeflowdetectionconditionsisnot
displayed.
Default: None (EXP is not contained in flow detection conditions.)
Range of value: 0-7
Flow Control Parameters
Flow control parameter
This parameter sets whether the contents of the band control set in this list are a
minimum guarantee band or maximum limitation band and whether the flow is
an important packet or normal packet when important packet protection (priority
band assignment) is performed in each band.
When the flow detected in this list is an important packet in a maximum
limitation band
When the flow detected in this list is a normal packet in a maximum limitation
band
When the flow detected in this list is an important packet in a minimum
guarantee band
When the flow detected in this list is a normal packet in a minimum guarantee
band
Default
None (The band control and important packet protection described above are not
performed.)
This parameter conforms to the conditions below when it is used.
Put the flow control parameter (UPC) of an important packet and normal packet
into the same setting state when performing important packet protection.
Theupc_penaltyoperationwhenthisparameterissetisasshowninthetable
below.