“A” Group: Standard Functions
Configuring
Drive Parameters
3–18
Automatic Voltage Regulation (AVR) Function
The automatic voltage regulation (AVR) feature keeps the inverter output waveform at a
relatively constant amplitude during power input fluctuations. This can be useful if the
installation has an erratic power source. However, the inverter cannot boost its motor
output to a voltage higher than the power input voltage. If you enable this feature, be
sure to select the proper voltage class setting for your motor.
“A” Function
Run-
time
Edit
Defaults DOP,DRW,DOP+
Func.
Code
Name Description
EU/
US
Units
Func.
Code
Name
A81 AVR function select Automatic (output) voltage
regulation, selects from three
type of AVR functions, three
option codes:
00...AVR enabled
01...AVR disabled
02...AVR enabled except
during deceleration
02 F-03 AVR
MODE
A82 AVR voltage select 200V class inverter settings:
.......200/220/230/240
400V class inverter settings:
.......380/400/415/440/460
230/
230,
400/
460
VF-03AVR AC
Technologies Inc.
Toll Free: voice: 1-877-539-2542 fax: 1-800-539-2542 www.mgitech.com